<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-14 12-50-49
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 78 dBuV P3 SR
Pilot RDS Phase Difference
6.4 kHz 4.8 kHz 77 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 35 kHz 19034 1,5499
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,9 dBr -0,27 dBr 0,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P3 SR " E203 10 (Pop M) 0 1 1 9 11:50, 14.06.2025
RT
"Digilistan med Emma Percival For Someone Else "
AF EON
97.9, 99.0, 99.4, 100.5 MHz E224, E201, E402
FM Scope Max at: 35 kHz MIN: 11 kHz % above 76 kHz: 1,5499 Acquired: 2025/06/14 12.49.45 Total samples: 19034 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,6 dBr MIN: -1,9 dBr AVE: -0,27 dBr % above 12,2 dBr: 0,0 Last value: 0,0 dBr (2025/06/14 12.49.45) 12.36 12.38 12.40 12.42 12.44 12.46 12.48 -2 -1 0 1 Pm [dBr]